      • Abstract

      Background
      Lung tumour motion poses a significant challenge in accurate delivery of radiotherapy. To prevent geographical miss, a generic margin is often added to the CTV to create an internal target volume (ITV). Studies have shown the effectiveness of Active Breathing Coordinator (ABC) (Elekta, Crawley, UK) in reducing this internal margin. For the purpose of this study we wanted to evaluate the feasibility of utilising ABC for our patient population and of defining ITV margin based on breath-hold scans.

      Methods
      13 patients receiving radical radiotherapy were prospectively recruited. Each patient received a 1 hour training session prior to CT simulation to determine eligibility for the study and provide training for the breath hold procedure. A minimum of fourteen seconds breath-hold was required for patients to be eligible. If eligible, patients were positioned on the CT simulator as per department protocol with the addition of ABC. Standard departmental CT protocol for lung treatment was first performed with contrast. This scan was used to identify the tumour region. A breath-hold scan at normal inspiration and expiration was done in the region of visible tumour volume with the aid of ABC. A radiation oncologist defined ITV based on current departmental protocol and using the ABC scans. To verify accuracy of ABC volume, a 4D Cone Beam CT (4D CBCT) scan was done during week 1 of treatment. To verify the reproducibility of ITV and breath-hold position, a second ABC scan and 4DCBCT were performed mid-way through treatment. The planning ITV and ABC ITV were compared. Variation in tumour position and volume were quantified and compared.

      Results
      From the 13 patients recruited, only 5 patients were able to tolerate ABC. On average, eligible patients were able to maintain a 20 second breath-hold. The generic ITV margin was larger than the patient specific ABC ITV margin in all cases. A change in centre of volume was noted between simulation ABC GTV and mid treatment ABC GTV. There was an average overall difference of 0.8cm for the 3 dimensional vectors for two eligible patients. There was no correlation between breath hold ability and the patient’s pulmonary function.

      Conclusion
      ABC was not feasible for the cohort of patients recruited for this study. For the patients who could tolerate ABC scans, the ITV could be individualized and reduced from that based on generic population data.